For over 60 years active in the market of the electromechanical construction and industrial plant engineering, Zamberlan is specialized in the design, development and construction of electrical panels MV/LV , becoming an important reference point in northern Italy for industrial installers, entities of distribution and manufacturing companies for the production of switchboards protected MV/LV.

Zamberlan produces switchboards protected of medium voltage air insulated since 1980 and SF6 gas insulated since 1995. Since 2010 it has introduced in the Italian market new compact compartments equipped with compact switch disconnector of maneuver and circuit breaker incorporated into a single device rotation.

The production, complying with European standard CEI EN 62271-200, allows a complete range of switchboards and systems of MV, which:

1054_99049
1

EsaMET 24kV

They are electrical panels of last generation, available both in the secure version and in the version of sealing to the inner arc, for nominal currents of 400A – 630A and with a nominal voltage of 24kV. The typology of the appliances is totally in SF6 gas for switch disconnectors / IMS line (new appliance GSec of ABB production), and gas SF6 (switch type HD4 of ABB production) or vacuum (switch type VD4 of ABB production) for the switches. The EsaMET’s series was subjected to tests (normalized pulse) into testing room, and it had obtained the certification referred to the IEC 694 and IEC 298 at the laboratories ABB SACE.

AirMET 24kV

They are electrical panels of protected type made for nominal currents of 400A – 630A – 800A – 1250A and with a nominal voltage of 24 kV.The typology of the electrical panels AirMET is mixed type, with switch disconnector disconnector of line (ABB production) of the type “rotary on-air” and with switch (it is also of ABB production) of the type gas SF6 (HD4) or vacuum (VD4).The AirMET’s series was subjected to tests of the type (normalized pulse) into testing room , and then it had obtained the certification referred to IEC 694 and IEC 298 at the Department of Electrical Engineering of the University of Padua and at the laboratories ABB SACE.

2
3

EsaMIX 24kV

They are electrical panels of modern conception, available in the protected version and in the version internal arc, for nominal currents of 400A – 630A and with a nominal voltage of 24kV.The typology of the appliances is totally in SF6 gas for switch disconnectors / IMS line (ABB production), and gas SF6 (switch type HD4/ABB production) or vacuum (switch type VD4/ABB production) for the switches.The ESAMIX’s series was subjected to tests type (normalized pulse) into testing room , and then it had obtained the certification referred to IEC 694 and IEC 298 at the laboratories ABB SACE.

TGI 24kV

1054_83654Compact medium voltage compartment with disconnection ing switch-switch in the air and in vacuum circuit breaker integrated in a single device rotating super compact. Ideal for use in small rooms. Widths 500 mm.

TGI is a new concept of integrated switch disconnector that offer this main characteristic:

  • MAXIMUM SAFETY IN THE PROTECTING THE OPERATOR
  • EASE OF UNIQUE MANEUVER
  • EXTREMELY COMPACT COMPARTMENT for narrow spaces

It install an insulated appliance in air which interrupts vacuum-sealed and sections in the air, without use of any gas. The TGI consider much more in consideration all aspects of the safety for the operator: it prevents errors in the sequence of the maneuvers and intelligently interacts with who performs them.It is made for nominal currents of 630 A and 1250 A and nominal voltage of 24kV, in compliance to the standards IEC 62271-100 and CEI 17-1. Dimensions: 500 x 975 x 1950 mm. The TGI is simple, it is equipped with mechanisms rationalized and devoid of complex commands, although complying with all the functional aspects and security.The TGI reproposes the safety of visible sectioning and respects the requested sequence of operations explicitly in the technical specifications of many institutions consumption and considering by these not eliminable:
1. open the circuit breaker
2. open the switch disconnector
3. close the earth

This sequence is concretised in TGI with an innovative method and a unique appliance. The TGI is compact and lightweight, inasmuch the vacuum-sealed interruption was combined with the sectioning in air , without use of SF6, in compliance of the Kyoto’s Protocol and ISO 14000.

5

AirMET 36kV

Classic compartment air-insulated medium voltage, with switch-disconnector switch in air and vacuum circuit breaker. Widths 1400-1300-800 mm.


They are protected switchboards made for nominal currents of 400A – 630A – 800A – 1250A and a rated voltage of 36kV. The type of AIRMET 36 kV switchboards is equipped with type SF6 gas switch disconnector (production SAREL) and SF6 gas type (HD4) or empty (VD4) circuit breaker (ABB production). The AIRMET 36 kV range has been subjected to type tests (standard pulse) at the indoor practice room, and then obtained the certifications related to the IEC 694 and IEC 298 at the department Ing. Electrical universities of Padua and in the Lab ABB SACE.